Cole-Parmer MP-100 Stuart Analogue Melting Point Apparatus 230 VAC
Cole-Parmer MP-100 Stuart Analogue Melting Point Apparatus 230 VAC
Product code: B8R04188
Product Description
The SMP11 is ideal for use in education, easy to use, with no complicated programming. Monitor samples through the magnifying lens and read the temperature on the included spirit-filled thermometer, see the sample more clearly with the integrated LED lamp.
The spirit filled mercury free thermometer, does not pose a health hazard in the event of a breakage.
The easy to follow instructions are printed directly on the apparatus.
The SMP 11 allows you to take the melting point of up to 3 samples at once for greater efficiency. The samples are placed in a melting point capillary tube and then inserted into the Aluminium block. The heating rate can be manually set between 1 and 20°C per minute, up to a maximum of 250°C.
- The apparatus is supplied with open ended capillary tubes, one end should be sealed using a Bunsen Burner, before use.
- Easy to operate
- Good visualisation
- GCSE to A-Level Chemistry: Melting Point investigations
- A high-range thermometer should be used with the melting point apparatus as the temperature exceeds the temperature range of a standard laboratory spirit thermometer.
- Lowering the heating rate as you near the expected melting point temperature will increase the accuracy of the reading.
Further Information
- Age Recommended from
- 11 Years
- Brand
- Cole-Parmer
- Heating Rate
- 1 - 20ºC
- Number of samples
- 3
- Temperature Range
- 50 - 250ºC
Documents
The SMP11 is ideal for use in education, easy to use, with no complicated programming. Monitor samples through the magnifying lens and read the temperature on the included spirit-filled thermometer, see the sample more clearly with the integrated LED lamp.
The spirit filled mercury free thermometer, does not pose a health hazard in the event of a breakage.
The easy to follow instructions are printed directly on the apparatus.
The SMP 11 allows you to take the melting point of up to 3 samples at once for greater efficiency. The samples are placed in a melting point capillary tube and then inserted into the Aluminium block. The heating rate can be manually set between 1 and 20°C per minute, up to a maximum of 250°C.
- The apparatus is supplied with open ended capillary tubes, one end should be sealed using a Bunsen Burner, before use.
- Easy to operate
- Good visualisation
- GCSE to A-Level Chemistry: Melting Point investigations
- A high-range thermometer should be used with the melting point apparatus as the temperature exceeds the temperature range of a standard laboratory spirit thermometer.
- Lowering the heating rate as you near the expected melting point temperature will increase the accuracy of the reading.
Further Information
- Age Recommended from
- 11 Years
- Brand
- Cole-Parmer
- Heating Rate
- 1 - 20ºC
- Number of samples
- 3
- Temperature Range
- 50 - 250ºC