Blue Spirit Filled Thermometer with Reversible Plastic Case - Total Immersion: -10 to +110, (L)150mm
Blue Spirit Filled Thermometer with Reversible Plastic Case - Total Immersion: -10 to +110, (L)150mm
Product code: B8A86204
Product Description
Pocket Test Thermometers, Spirit - Blue
-10 to +110°C
Reversible plastic case thermometer - the clear body fits to the cap with a bayonet clip which allows the case to be reversed and used as a holder for the test thermometer to avoid contact with the material being tested.
Specification:
- Range (°C): -10°C to +110°C
- Division: 1°C
- Accuracy: +/-1.5°C at 90°C
- Immersion: Total
- Product Material: Glass Tube: Kerosene filled, Clear Pocket Case: Random Co Polymer
- Component Weights: Plastic - 6g, Glass: 11g
- Product Weight: 17g
- Product Dimensions: 150 x 15mm
- Immersion depth: Thermometers available are total or partial immersion. Total immersion thermometers are designed to give correct readings when completely immersed in the medium under test. Partial immersion thermometers are calibrated to read correctly when immersed to defined depth (usually 76mm)
- Faults during transit. Thermometers may develop faults during transit or when otherwise subject to undue vibration. Most faults can be corrected by following these suggestions:
- Gas trapped in bulb. Tap any bubbles of gas into the top of the bulb then cool the bulb in a suitably cold medium. As the spirit contracts the trapped gas should be forced above the spirit
- Broken thread. The spirit thread may be re-joined by cooling
- Detached spirit at the top of contraction chamber. Cool the bulb until spirit comes down into the contraction chamber. The side of the stem should be gently tapped until the detached spirit forms a globule on the wall of the contraction chamber. By gently heating the bulb this spirit can be re-joined to the main column
- Detached spirit in the expansion chamber. Tap the top of the stem until the detached spirit collects at the top of the capillary. Very carefully heat the thermometer. As the expanding spirit forces gas into the expansion chamber, continue to tap the stem in order to keep the detached spirit on top of the capillary
- Maximum/minimum thermometers. For broken threads, hold at the top and give a sharp shake
Further Information
- Accuracy
- 1.5°C
- Brand
- BrannanUnbranded
- Division
- 1°C
- Filling
- Kerosene
- Immersion
- Total Immersion
- Length
- 150mm
- LO-Tox
- Yes
- Offers
- Reduced
- Pocket Size
- Yes
- Product Type
- Laboratory Thermometer (in plastic case)
- Range
- -10°C to +110°C
- Spirit Colour
- Blue
- Thermometer Type
- Spirit
Documents
Pocket Test Thermometers, Spirit - Blue
-10 to +110°C
Reversible plastic case thermometer - the clear body fits to the cap with a bayonet clip which allows the case to be reversed and used as a holder for the test thermometer to avoid contact with the material being tested.
Specification:
- Range (°C): -10°C to +110°C
- Division: 1°C
- Accuracy: +/-1.5°C at 90°C
- Immersion: Total
- Product Material: Glass Tube: Kerosene filled, Clear Pocket Case: Random Co Polymer
- Component Weights: Plastic - 6g, Glass: 11g
- Product Weight: 17g
- Product Dimensions: 150 x 15mm
- Immersion depth: Thermometers available are total or partial immersion. Total immersion thermometers are designed to give correct readings when completely immersed in the medium under test. Partial immersion thermometers are calibrated to read correctly when immersed to defined depth (usually 76mm)
- Faults during transit. Thermometers may develop faults during transit or when otherwise subject to undue vibration. Most faults can be corrected by following these suggestions:
- Gas trapped in bulb. Tap any bubbles of gas into the top of the bulb then cool the bulb in a suitably cold medium. As the spirit contracts the trapped gas should be forced above the spirit
- Broken thread. The spirit thread may be re-joined by cooling
- Detached spirit at the top of contraction chamber. Cool the bulb until spirit comes down into the contraction chamber. The side of the stem should be gently tapped until the detached spirit forms a globule on the wall of the contraction chamber. By gently heating the bulb this spirit can be re-joined to the main column
- Detached spirit in the expansion chamber. Tap the top of the stem until the detached spirit collects at the top of the capillary. Very carefully heat the thermometer. As the expanding spirit forces gas into the expansion chamber, continue to tap the stem in order to keep the detached spirit on top of the capillary
- Maximum/minimum thermometers. For broken threads, hold at the top and give a sharp shake
Further Information
- Accuracy
- 1.5°C
- Brand
- BrannanUnbranded
- Division
- 1°C
- Filling
- Kerosene
- Immersion
- Total Immersion
- Length
- 150mm
- LO-Tox
- Yes
- Offers
- Reduced
- Pocket Size
- Yes
- Product Type
- Laboratory Thermometer (in plastic case)
- Range
- -10°C to +110°C
- Spirit Colour
- Blue
- Thermometer Type
- Spirit